Water-based suppression

Automatic fire suppression systems: sprinklers, pump stations, hydrants

For residential complexes, shopping centres, warehouses, car parks and industrial sites we design, install and maintain water-based automatic suppression: sprinkler networks (wet, dry, deluge, pre-action), water mist, fire pump stations, internal and external hydrants. Designs are approved with the fire authority and the equipment is certified.

  • 4 sprinkler types + water mist
  • Pump stations and hydrants
  • Fire authority approval
  • Water mist system at the Olympic Stadium
Fire pump station: pumps and control cabinet
  • Fire pump station: pumps and control cabinet
  • Pump station pipework and valves
  • Sprinkler head types: demo stand
  • External fire hydrant on a site

Types of sprinkler systems

A sprinkler head opens only when heat reaches it, so water goes only where the fire is. The system type depends on room temperature, fire load and how critical a false discharge would be.

  • Wet system

    Pipes are always full of water; it flows as soon as a head opens. The simplest and most common type: offices, shopping centres, residential buildings, heated warehouses.

  • Dry system

    Pipes hold compressed air or nitrogen; water enters after the valve. For places at risk of freezing: unheated warehouses, open car parks, cold stores.

  • Deluge system

    Heads are open; the valve is released by the fire alarm and the whole zone is flooded. For fast-spreading fire risks: transformers, fuel, chemical stores.

  • Pre-action system

    Water is released only when a detector and a head both trigger, minimising accidental discharge. Server rooms, archives, museums.

Water mist systems

High pressure turns water into very fine droplets: heat is removed quickly with little water and oxygen is limited. For large areas with many people and where water damage must stay low. At Baku Olympic Stadium we installed the water mist and FM-200 systems and service them periodically.

Fire pump stations and hydrants

The pump station gives the sprinkler and hydrant network the required pressure and flow: main electric pump, standby (diesel or second electric) pump, jockey pump, control cabinet, valves. Internal hydrants (landing valves) go on each floor, external hydrants across the site. We work with Turkuaz Pompa, Kızılkaya, Armaş, Shield and Duyar equipment.

  • Pump station calculation and installation
  • Pipework, gate valves, check valves
  • Internal landing valves and cabinets
  • External hydrants and connection to the water tank

Which sites it suits

Residential complexes and high-rise buildings, shopping centres and hotels, warehouses and logistics centres, underground and multi-storey car parks, industrial sites, stadiums and public buildings. For construction companies and fit-out contractors we work from the design stage.

How the work goes

Site visit or review of the design documents, choice of system type by fire load, hydraulic calculation, fire authority approval, equipment supply, installation and pressure test, commissioning certificate. Then periodic checks of pumps, valves and heads under an annual contract.

Projects

Projects where we installed this system

Brands we use for this system

Frequently asked questions

Questions about this service

A wet system for a heated warehouse, a dry system for an unheated or cold one. High racks and combustible goods need special heads and densities. The exact answer depends on fire load and rack height.

Contact

Free calculation for your project

Send the site plan or book a visit: we prepare the system type, the pump station and the quote.

Baku office

Baku, Narimanov district, Ağa Nemətulla str. 247

+994 50 453 33 45 · info@safetysolutions.az

Mon–Fri 09:00–18:00 · emergencies 24/7

Send a request

Your details are used only to answer your request.

CallWhatsApp